Precision alignment and guide system to achieve the angular alignment and guiding requirements in the Test Procedure.Reaction moment is measured directly. No conversions or calculations,
weights or approximations to induce errors in the moment measurement.as the moment. This centerline is lined up with the center of rotation of the femur by matching tolerances for precise alignment. This provides maximum accuracy and requires no setup adjustments.Test Stand is controlled by a digital controller
Purpose and Function
It can be used for the calibration test of the buttocks of Hybrid III 50 and Hybrid III 5 dummies, meeting the requirements of NHTSA, 49CFR PART572, SAE, JJF, etc.
Compliant standards
CFR 49 Part 572
JJF 1230-2009 《Specification for calibration of vehicle frontal collision test equipment》
Sensor and data collector full SAE J211《Impact testing instrument》
Dimensions | External Dimensions(mm) | Work Area(mm) |
Length | 1263 | 1679 |
Width | 877 | 877 |
Height | 1844 | 1844 |

Copy product links
Long by picture save/share